Skip to main content
Home

Navegación principal

  • Home
  • Support
    • User's guide
    • Code & Development
OpenID Connect login

servicePortsInfo

By abdelkader.ziani, 17 November, 2024
Output
Terminal output of remote execution
Action: servicePortsInfo at 11/17/2024, 1:31:16 PM


Huawei Integrated Access Software (MA5800).
Copyright(C) Huawei Technologies Co., Ltd. 2002-2019. All rights reserved.

-----------------------------------------------------------------------------
User last login information:
-----------------------------------------------------------------------------
Access Type : SSH
IP-Address : 10.228.153.11
Login Time : 2024-11-17 14:29:06+08:00
Logout Time : 2024-11-17 14:29:07+08:00
-----------------------------------------------------------------------------

MA5800-X7-ORKOYEN>scroll512

MA5800-X7-ORKOYEN>enable

MA5800-X7-ORKOYEN#config

MA5800-X7-ORKOYEN(config)#display service-port port 0/2/5 ont 1
{ <cr>|e2e<K>|gemport<K>|sort-by<K>||<K> }:

Command:
display service-port port 0/2/5 ont 1
Switch-Oriented Flow List
-----------------------------------------------------------------------------
INDEX VLAN VLAN PORT F/ S/ P VPI VCI FLOW FLOW RX TX STATE
ID ATTR TYPE TYPE PARA
-----------------------------------------------------------------------------
253 103 common gpon 0/2 /5 1 2 vlan 103 10 10 up
254 7 common gpon 0/2 /5 1 1 vlan 7 1000 1000 up
-----------------------------------------------------------------------------
Total : 2 (Up/Down : 2/0)
Note : F--Frame, S--Slot, P--Port,
VPI indicates ONT ID for PON, VCI indicates GEM index for GPON,
v/e--vlan/encap, pritag--priority-tagged,
ppp--pppoe, ip--ipoe, ip4--ipv4oe, ip6--ipv6oe, vxl--vxlan.
When FLOW TYPE is plist, the value of FLOW PARA is a byte in
hexadecimal format and indicates a priority list. Eight bits
of its binary value indicate priorities 0-7 from the least
significant bit to the most significant bit. Value 1 indicates
that the priority is used. For example, if FLOW PARA is 0x23 and
its binary format is 0010 0011, priorities 0, 1 and 5 are used

MA5800-X7-ORKOYEN(config)#

MA5800-X7-ORKOYEN(config)#quit

MA5800-X7-ORKOYEN#quit
Check whether system data has been changed. Please save data before logout.
Are you sure to log out? (y/n)[n]:y

Configuration console exit, please retry to log on
retCode
255
Canal RSS
Powered by Drupal