servicePortsInfo

By carles.casanova, 17 June, 2025
Output
Terminal output of remote execution
Action: servicePortsInfo at 6/17/2025, 9:13:33 AM


Huawei Integrated Access Software (MA5800).
Copyright(C) Huawei Technologies Co., Ltd. 2002-2017. All rights reserved.

-----------------------------------------------------------------------------
User last login information:
-----------------------------------------------------------------------------
Access Type : SSH
IP-Address : 10.228.153.11
Login Time : 17-06-2025 11:12:18+02:00 DST
Logout Time : 17-06-2025 11:12:19+02:00 DST
-----------------------------------------------------------------------------

OLTRibera_Ebre>scroll 512

OLTRibera_Ebre>enable

OLTRibera_Ebre#config

OLTRibera_Ebre(config)#display service-port port 0/6/0 ont 4
{ <cr>|e2e<K>|gemport<K>|sort-by<K>||<K> }:

Command:
display service-port port 0/6/0 ont 4
Switch-Oriented Flow List
-----------------------------------------------------------------------------
INDEX VLAN VLAN PORT F/ S/ P VPI VCI FLOW FLOW RX TX STATE
ID ATTR TYPE TYPE PARA
-----------------------------------------------------------------------------
219 103 common gpon 0/6 /0 4 1 vlan 103 10 10 up
220 165 QinQ gpon 0/6 /0 4 2 vlan other-all 11 11 up
221 165 QinQ gpon 0/6 /0 4 3 vlan other-all 1000 1000 up
-----------------------------------------------------------------------------
Total : 3 (Up/Down : 3/0)
Note : F--Frame, S--Slot, P--Port,
VPI indicates CM index for DOCSIS,
VPI indicates ONT ID for PON, VCI indicates GEM index for GPON,
v/e--vlan/encap, pritag--priority-tagged,
ppp--pppoe, ip--ipoe, ip4--ipv4oe, ip6--ipv6oe.
When FLOW TYPE is plist, the value of FLOW PARA is a byte in
hexadecimal format and indicates a priority list. Eight bits
of its binary value indicate priorities 0-7 from the least
significant bit to the most significant bit. Value 1 indicates
that the priority is used. For example, if FLOW PARA is 0x23 and
its binary format is 0010 0011, priorities 0, 1 and 5 are used

OLTRibera_Ebre(config)#

OLTRibera_Ebre(config)#quit

OLTRibera_Ebre#quit
Check whether system data has been changed. Please save data before logout.
Are you sure to log out? (y/n)[n]:y

Configuration console exit, please retry to log on
retCode
255
Canal RSS